FRAMING · FOUNDATIONS · BC✦INSURED✦PREFAB WALL SYSTEMS✦FREE QUOTE IN 48 HRS✦778-403-6987✦INFO@OGPREFAB.COM✦FRAMING · FOUNDATIONS · BC✦INSURED✦PREFAB WALL SYSTEMS✦FREE QUOTE IN 48 HRS✦778-403-6987✦INFO@OGPREFAB.COM✦FRAMING · FOUNDATIONS · BC✦INSURED✦PREFAB WALL SYSTEMS✦FREE QUOTE IN 48 HRS✦778-403-6987✦INFO@OGPREFAB.COM✦FRAMING · FOUNDATIONS · BC✦INSURED✦PREFAB WALL SYSTEMS✦FREE QUOTE IN 48 HRS✦778-403-6987✦INFO@OGPREFAB.COM✦
Request a Quote→778-403-6987→
Foundation

Crawl Space Foundation Construction in Victoria, BC: How It Is Built

A crawl space foundation puts the main floor on short concrete foundation walls and footings, with a low space between the ground and the floor framing. It suits Greater Victoria lots that slope, sit on rock, or need room under the floor for plumbing, ducts and drains. This guide walks through how one is built, step by step, and the BC Building Code requirements behind each step. If you are still choosing between a slab, a crawl space and a basement, start with our foundation types guide.

Pro tip: This is general planning information, not engineering, code or legal advice. Footing depth, wall design, insulation, ventilation and radon measures are set by your drawings, your designer or engineer, the BC Building Code and your municipality. The BC Building Code 2024 applies to projects with building permits applied for after March 8, 2024. Confirm each item for your own lot.

First Decision: Vented or Heated Crawl Space

Before anything is formed, the drawings need to say whether the crawl space is unheated (vented to the outdoors) or heated (inside the building envelope, often called a conditioned crawl space). Article 9.18.1.3 of the BC Building Code treats a crawl space as heated where it is used as a hot air plenum, contains heating ducts that are not sealed and insulated to minimize heat loss to the space, or is not separated from heated space in accordance with Section 9.25. So a crawl space with heating ducts running through it that are not sealed and insulated counts as heated whether or not anyone planned it that way. Heated crawl spaces need insulation, an air barrier system and a vapour barrier in their walls.

ItemUnheated (vented)Heated
VentilationNatural or mechanical, Article 9.18.3.1Section 9.32, Article 9.18.3.2
Ground coverAsphalt, concrete, roll roofing or polyethylene, Article 9.18.6.1Sealed polyethylene as part of the air barrier, Article 9.18.6.2
Insulation lineUsually the floor aboveThe crawl space walls, Section 9.25
Footing depth columnNo heated spaceHeated basement or crawl space, unless the foundation is insulated to reduce heat flow to the soil beneath the footings

Step 1: Excavation and Footings

The dig is shallower than for a basement, but the same rules apply. Article 9.12.1.1 requires the bottom of every excavation to be free of organic material. Article 9.12.2.1 says excavations for foundations shall extend to undisturbed soil, and Article 9.12.1.2 says they shall be kept free of standing water, which takes planning in a Victoria winter. Our foundation excavation guide covers locates, rock and shoring, and the excavation volume calculator gives a rough sense of how much material comes out.

Footing depth comes from Table 9.12.2.2 and depends on the soil and on whether the foundation contains heated space. On rock the table sets no limit. For clay or soils not clearly defined the minimum is 1.2 m with heated space, and 1.2 m but not less than the depth of frost penetration with no heated space. With no heated space, silt also has to go below the depth of frost penetration, and so does coarse-grained soil with poor drainage; with heated space, the table sets no limit for either. A vented crawl space is generally read as a foundation containing no heated space, so on those soils it can need deeper footings than the same house with a heated crawl space; confirm with your designer which column the drawings use. A foundation insulated to reduce heat flow to the soil beneath the footings also moves into the no-heated-space column (Sentence 9.12.2.2.(2)), and Sentence 9.12.2.2.(5) allows lesser depths where local experience or the foundation design supports them. The geotechnical report and the drawings settle the number.

Step 2: Foundation Walls

Article 9.18.1.2 sends crawl space foundations to Section 9.15, the general Part 9 rules for footings and foundation walls. Two details matter on almost every job: Article 9.15.4.6 requires exterior foundation walls to extend not less than 150 mm above finished ground level, and Article 9.3.2.9 requires structural wood to be pressure-treated against decay where its clearance to finished ground is less than 150 mm. On a sloped lot, check both at the low side of the house, where final grading tends to creep up the wall.

On sloped Victoria lots the footings usually step down the hill, so wall heights change along the run while the top of wall still has to land level for the floor framing. Getting that elevation right is what lets the floor system, or prefab wall panels above it, go down without shimming; our post on coordinating the foundation with prefab panel delivery explains why. The foundation concrete calculator helps rough out footing and wall volumes.

Step 3: Drainage

Article 9.18.5.1 says that, except where it can be shown to be unnecessary, the ingress of water into a crawl space shall be controlled by grading or drainage. Under Article 9.14.2.1 the bottom of every exterior foundation wall is drained by drainage tile or pipe around the exterior of the foundation, or by a layer of gravel or crushed rock, unless it can be shown to be unnecessary. In practice: grade the crawl space floor so water has somewhere to go, lay the perimeter drain before backfill, and steer surface water from the slope above around the house. This guide to perimeter drain replacement in Victoria shows what a working drain looks like.

Step 4: Ground Cover

For an unheated crawl space, Article 9.18.6.1 requires a ground cover of not less than 50 mm of asphalt, 100 mm of 15 MPa Portland cement concrete, Type S roll roofing, or 0.10 mm polyethylene, with sheet joints lapped not less than 100 mm and weighted down.

A heated crawl space needs more. Article 9.18.6.2 requires not less than 0.15 mm polyethylene conforming to CAN/CGSB-51.34-M, installed as part of the air barrier system, with joints lapped not less than 300 mm and either sealed and evenly weighted down or covered with at least 50 mm of concrete. The perimeter is sealed to the foundation wall and every penetration is sealed against air leakage. Plumbing and service penetrations are the hardest part of the cover to seal well, so plan them before the poly goes down.

Step 5: Ventilation

Article 9.18.3.1 requires unheated crawl spaces to be ventilated by natural or mechanical means. With natural ventilation the code asks for not less than 0.1 m2 of unobstructed vent area for every 50 m2 of floor area, with vents uniformly distributed on opposite sides of the building and designed to keep out snow, rain and insects. Put the vents on the foundation drawings so they are formed in, not cut later. Heated crawl spaces are ventilated under Section 9.32 instead, as part of the mechanical design for the house.

Step 6: Access Hatch and Service Room

Article 9.18.2.1 requires an access opening of not less than 500 mm by 700 mm for a crawl space serving a single dwelling unit, and 550 mm by 900 mm for other crawl spaces, fitted with a door or hatch unless the crawl space is heated and reached from an adjacent heated space. Where cleanouts, traps or burners sit in the crawl space, Article 9.18.4.1 requires an access way at least 600 mm high and wide from the access door to the equipment, and for 900 mm on the side or sides to be serviced. That rule can drive wall height, so place equipment before foundation heights are fixed.

Step 7: Radon and Soil Gas

The code's explanatory Note A-9.13.4 describes radon as a colourless, odourless, radioactive gas found in soil gas in all regions of Canada that "is known to enter dwelling units by infiltration into basements and crawl spaces", and warns that a radon problem "may only become apparent once the building is completed and occupied." That is why protection goes in during construction.

Subsection 9.13.4 requires assemblies separating conditioned space from the ground to be protected by an air barrier system, plus either a rough-in for a future subfloor depressurization system, a space designed to stay accessible for one, or a Part 5 and 6 design. In a heated crawl space, Article 9.18.6.2 makes the sealed polyethylene ground cover part of that air barrier system. In a vented crawl space, the floor above is generally treated as the separation between the house and the crawl space; that is a common reading, not code text. Ask your designer to show which route applies so the crew forms, seals and sleeves the right things.

What to Settle Before Forming

  1. 1Heated or unheated, written on the drawings, with the insulation line shown.
  2. 2Geotechnical report, footing elevations and any step footings.
  3. 3Top of wall elevations matched to the floor system or panel drawings.
  4. 4Vent locations (unheated) or the ventilation design (heated).
  5. 5Access hatch location and where cleanouts and equipment will sit.
  6. 6Ground cover type and how penetrations will be sealed.
  7. 7Radon route: rough-in, accessible space or engineered design.
  8. 8Perimeter drain, crawl space drainage and the discharge point.
  9. 9Footing and foundation inspections booked against the pour dates.

Who carries each item varies by project. Our post on what a framing and foundation company covers explains where the scope usually starts and stops, so nothing on this list falls between trades.

Frequently Asked Questions

How deep do crawl space footings need to be in Victoria BC?

Table 9.12.2.2 of the BC Building Code sets minimum depths by soil type and by whether the foundation contains heated space. Rock has no limit; clay or soils not clearly defined start at 1.2 m, and with no heated space must also reach the depth of frost penetration. Your geotechnical report and drawings set the actual depth.

Does a crawl space need a vapour barrier in BC?

An unheated crawl space needs a ground cover under Article 9.18.6.1, such as 0.10 mm polyethylene with lapped, weighted joints. A heated crawl space needs at least 0.15 mm polyethylene installed as part of the air barrier system and sealed at the perimeter and penetrations, under Article 9.18.6.2.

Do crawl spaces need vents in BC?

Unheated crawl spaces must be ventilated by natural or mechanical means under Article 9.18.3.1. Heated crawl spaces follow Section 9.32 instead.

How big does a crawl space access hatch need to be?

At least 500 mm by 700 mm for a crawl space serving a single dwelling unit, and 550 mm by 900 mm for other crawl spaces, under Article 9.18.2.1.

Does OG Prefab build crawl space foundations?

Yes. We build footings and foundation walls across Greater Victoria and coordinate them with the framing on top. Send your drawings and we will state in writing what is included.

Planning a crawl space foundation in Greater Victoria? Send the drawings and the site address and we will come back with a written foundation quote, with the crawl space details spelled out.

Request a Foundation Quote

Ready to build in Victoria, BC?

We serve Victoria, Saanich, Oak Bay, Langford, Colwood, View Royal, and all of Greater Victoria. Free estimate with no obligation.

Request a Free Quote